- Higher than NEMA service factor dual compartment motor
- Designed for continuous duty
- Built-in check valve
- Handles solids up to 1/4" (6.4 mm) diameter
- 1-1/4" (31.75 mm) NPT discharge
- 120 °F (49 °C) liquid temperature rating
- CSA listed
-
HP Volts Hz Amps Watts Performance (GPM @ Height in Feet) Shut-Off (ft) PSI FLA Start 20 ft 25 ft 30 ft 35 ft 40 ft 45 ft 50 ft 1/2 115/230 60 8.4/4.2 42/21.60 810 45 39 31 24 16 8 – 50 21.6 3/4 115/230 60 14.3/7.1 71.5/36.2 1000 58 53 44 36 29 18 10 56 23.8 Item No. Model HP Volts Switch Type/Operation Weight 621815 BE-S50 1/2 115/230 Manual 42 lbs 19.05 Kg 621825 BE-S75 3/4 115/230 Manual 49 22.23 Kg