Battery Backup System with Primary Pump

Battery Backup System with Primary Pump

Applications

  • Secondary sump pump
  • Flood protection
  • Emergency Dewatering
Features
Order Info
Downloads
  • Features

    • 12 VDC backup pump
    • Durable non-corrosive pump housing with stainless steel fasteners
    • Easily removed bottom suction screen for serviceability and maintenance
    • 115 VAC primary pump
    • Heavy-duty cast iron construction
    • Energy-efficient permanent split capacitor (PSC) motor with automatic reset thermal overload protection
    • 1-1/2" FNPT discharge piping size
    • Lift ring for easy and quick installation
    • Diaphragm switch
    • Check valve, elbow connector, and pump coupling
    • ƒBattery box holds size 27, 12 V deep cycle battery (battery not included)
    • *Recommended 12 VDC deep cycle battery, lead acid or AGM
    • Model 506411
    • 12 VDC backup pump
    • 42 gpm (159 lpm) at 0 ft (0 m) and 20 ft (6.1 m) shut-off
    • 10 amp controller/charger/alarm unit
    • 1/3 hp, 115 VAC primary pump
    • 53 gpm (201 lpm) at 5 ft (1.5 m) of lift and 28 ft (8.5 m) shut-off
    • Model 506410
    • 12 VDC backup pump
    • 53 gpm (201 lpm) at 0 ft (0 m) and 23 ft (7 m) shut-off
    • 12 amp controller/charger/alarm unit
    • 1/2 hp, 115 VAC primary pump
    • 67 gpm (254 lpm) at 5 ft (1.5 m) of lift and 36 ft (11 m) shut-off
  • Item NumberModel Number
    506411SPBS-10HF-6
    Charging Unit
    Item
    Number
    Model
    Number
    VoltsHzMax Input Amps
    at 115 VAC
    Max Output Amps at 12 VDCWattsCord
    (ft)
    Weight
    (lbs)
    Battery Leads (ft)
    1064691210HF115 VAC603103456 ft56 ft
    Backup Pump Switch
    Item
    Number
    Model
    Number
    VoltsHzSwitch On LevelSwitch Off LevelWattsCord (ft)Weight (lbs)
    105601RS-1212 VDC-13.5"9"-9 ft0.5
    Backup Pump
    Item
    Number
    Model
    Number
    VoltsHzAmpsWattsGPM @ Height in FeetShut-Off
    (ft)
    PSICord
    (ft)
    Weight
    (lbs)
    FLAStart0 ft5 ft10 ft
    106963250012 VDC-143216842292020 ft8.76 ft6
    Primary Pump
    Item
    Number
    Model
    Number
    VoltsHzHpAmps FLAWattsGPM @ Height in FeetShut-Off
    (ft)
    PSICord
    (ft)
    Weight
    (lbs)
    5'10'15'20'
    5068076EC-CIA-SFS115 VAC601/356005350423428'11.710'30
    Item NumberModel Number
    506410SPBS-12HF-10
    Charging Unit
    Item
    Number
    Model
    Number
    VoltsHZMax Output Amps at 12 VDCWattsCord (ft)Weight (lbs)Battery Leads (ft)
    FLASTART
    1064861212HF115 VAC60312345656
    Backup Pump Switch
    Item
    Number
    Model
    Number
    VoltsHzSwitch On LevelSwitch Off LevelWattsCord (ft)Weight (lbs)
    105601RS-1212 VDC-13.5"9"-90.5
    Backup Pump
    Item
    Number
    Model
    Number
    VoltsHzAmpsGPM @ Height in FeetShut-Off (ft)PSICord (ft)Weight
    (lbs)
    FLAStartWatts0 ft5 ft10 ft15 ft
    106961336012 VDC-153218053392413231066
    Primary Pump
    Item
    Number
    Model
    Number
    VoltsHzHPAmps FLAWattsGPM @ Height in FeetShut-Off
    (ft)
    PSICord
    (ft)
    Weight
    (lbs)
    5 ft10 ft20 ft30 (ft)
    51080310EC-CIA-SFS115 VAC601/26.57506757472836 ft15.610 ft26